Metglas® 2714A Magnetic Alloy
| General Properties & Characteristics | |
|---|---|
| ELECTROMAGNETIC | |
| Saturation Induction (T) | 0.57 |
| Maximum DC Permeability (µ) | |
| Annealed | 1,000,000 |
| As Cast | >80,000 |
| Saturation Magnetostriction (ppm) | <0.5 |
| Electrical Resistivity (µΩ-cm) | 142 |
| Curie Temperature (°C) | 225 |
| PHYSICAL | |
| Thickness (microns) | 15 |
| Standard Available Widths | |
| Minimum (mm) | 2.5 |
| Maximum (mm) | 50 |
| Density (g/cm3) | 7.59 |
| Vicker's Hardness (50g Load) | 960 |
| Tensile Strength (GPa) | 1-2 |
| Elastic Modulus (GPa) | 100-110 |
| Lamination Factor (%) | >75 |
| Thermal Expansion (ppm/°C) | 12.7 |
| Crystallization Temperature (°C) | 550 |
| Continuous Service Temp. (°C) | 90 |
APPLICATIONS:
- Switch-mode power supply
- magnetic amplifiers
- semiconductor noise suppression cores
- High frequency transformers
- High sensitivity matching transformers
- Ultra-sensitive current sensors
- Shielding
- Magnetic sensor applications
BENEFITS:
- Extremely low core loss
- Ultrahigh permeability
- High squareness ratio - low coercive force
- Excellent corrosion resistance
- Can be annealed for linear BH loop
2714A
Material safety Data Sheet
Typical DC Hysteresis Loop
MetglasĀ® Alloy 2714A
Typical Impedance Permeability Curves
MetglasĀ® Alloy 2714A
No-Field Anneal

Typical Core Loss Curves
MetglasĀ® Alloy 2714A
No-Field Anneal